EUCLIDES

Monitoring system

A modular environmental monitoring system connecting multiple ELSE NUCLEAR detectors to a local control unit.

Control unit
Wall-mounted local control unit with panel PC1
Compatible detectors
ELSE NUCLEAR detectors; selected for the system1
Radiation types
Depends on connected detectors, e.g. gamma or neutrons1
Communication
Ethernet to external PC2

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Multiple detectors can operate simultaneously.
  • Software for data acquisition and management.
  • Alarm column and network communication.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Compatible detectorsELSE NUCLEAR detectors; selected for the system1
Radiation typesDepends on connected detectors, e.g. gamma or neutrons1

Software & data

External softwareCompatible with 5700 sMON2

Connectivity & interface

CommunicationEthernet to external PC2

General

Control unitWall-mounted local control unit with panel PC1
Data acquisitionReal-time acquisition from connected detectors2
Archiving and exportNumeric data and graphs; spreadsheet-compatible export2
AlarmContinuous threshold monitoring; LED and siren alarm column2
Access controlPassword-protected settings2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ELSE NUCLEARProduct page product page Checked 2026-10-16
  2. 2
    Publisher: ELSE NUCLEARDatasheet p. 2; p. 1 Checked 2026-10-16
FREE-AND 16
ELSE NUCLEAR

FREE-AND 16

Spectrometric station with 16 NaI(Tl) for waste characterisation

Detector type
16 NaI(Tl) 3 × 3 in crystals with PMT and MCA, eight on each side in two arrays
9 referenced values
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ARCHIMEDES III
ELSE NUCLEAR

ARCHIMEDES III

Portal monitor for excavation materials in boxes and containers

Detector type
Four plastic scintillators 100 × 50 × 5 cm
Active area
5000 cm² per detector; two pairs mounted on the sides of the portal
Energy range
35 keV–2 MeV
8 referenced values
ADAMOS
ELSE NUCLEAR

ADAMOS

Automated segmented gamma scanning of waste drums

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.