AMETEK Scientific InstrumentsSolartron Analytical

1451A FRA-modul

FRA module

1451A by Solartron Analytical. FRA module. Required equipment and compatibility: CellTest 1470E and 1400A chassis.

Frequency range
10 µHz–100 kHz1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Frequency range: 10 µHz–100 kHz
  • Host requirement: CellTest 1470E and 1400A chassis
  • Communication: Ethernet 10/100BaseT

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Frequency range10 µHz–100 kHz1
Host systemCellTest 1470E and 1400A chassis1
CommunicationEthernet 10/100BaseT2
Generator amplitude50 µV–3 V RMS2
Generator impedance50 Ω2
Auxiliary inputs4 differential channels per FRA; requires 14702A/14703A2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: AMETEK Scientific InstrumentsProduct page Overview – Simultaneous Impedance; Overview – CellTest 1470E; CellTest Options for Configuration Checked 2026-10-16
  2. 2
    Publisher: AMETEK Scientific InstrumentsBrochure p. 7, 145x Frequency Response Analyzer Specification – General; p. 7, 145x Frequency Response Analyzer Specification – Generator; p. 7, Auxiliary Voltage Analyzers Checked 2026-10-16
ModuLab XM MTS materialtestsystem
AMETEK SI

ModuLab XM MTS materialtestsystem

Materials test system

Impedance range
10 µΩ–100 TΩ depending on module configuration
EIS frequency range
10 µHz–1 MHz with XM MFRA 1MHz
Maximum output current
XM MAT: ±100 mA; XM MBST 2A: ±2 A (option)
6 models
ModuLab XM ECS
AMETEK SI

ModuLab XM ECS

Configurable electrochemical system

Compliance voltage
±8 V standard; ±30 V / ±100 V with HV options
8 models
PARSTAT MC
AMETEK SI

PARSTAT MC

Modular multichannel system

Measurement channels
Up to 20 with PMC-200; up to 10 with PMC-1000 or PMC-2000A
Compliance voltage
PMC-200: ±10 V; PMC-1000: ±12 V; PMC-2000A: ±30 V
3 models