Active area
32 cm² (A 32), 31 cm² (AB 31), 100 cm² (AB 100, A-B 100), 170 cm² (AB 170, A-B 170, A-BG 170)1
Measurement range
α: 0.01–100 Bq/cm²; β and α+β: 0.1–1,000 Bq/cm²; AB 31: 0.1–2,150 Bq/cm²1
Energy range
α: 3–8 MeV; β: 100 keV–2.2 MeV1

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Embedded alarm and distance indicator
  • Ruggedised design for the nuclear industry
  • Floor stand for a mobile checkpoint

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeA 32: ZnS (α); AB 31: double GM pancake (α+β); AB 100 and AB 170: thin plastic scintillator (α+β); A-B 100 and A-B 170: ZnS + thin plastic scintillator (separate α and β channels); A-BG 170: ZnS + thick plastic scintillator (α, and β and γ)1
Active area32 cm² (A 32), 31 cm² (AB 31), 100 cm² (AB 100, A-B 100), 170 cm² (AB 170, A-B 170, A-BG 170)1
Proximity sensor and alarmProximity sensor and radiation alarm on all probes1

Measuring range

Sensitivity (c/s/Bq)A 32: 0.16 (²³⁹Pu); AB 31: 0.21 (³⁶Cl); AB 100: 0.29 (³⁶Cl); A-B 100: α 0.14 (²⁴¹Am), β 0.23 (³⁶Cl); AB 170: 0.29 (³⁶Cl); A-B 170: α 0.15, β 0.25; A-BG 170: α 0.16, β 0.281
Measurement rangeα: 0.01–100 Bq/cm²; β and α+β: 0.1–1,000 Bq/cm²; AB 31: 0.1–2,150 Bq/cm²1
Energy rangeα: 3–8 MeV; β: 100 keV–2.2 MeV1

Mechanical

DimensionsA 32: 264 × 119 × 123 mm; AB 31: 124 × 74 × 190 mm; 100 cm² probes: 293 × 119 × 121 mm; 170 cm² probes: 308 × 143 × 128 mm (L × W × H)1
WeightA 32 and 100 cm² probes: 600 g; AB 31: 630 g; 170 cm² probes: 740 g1

Ordering & accessories

ModelsA 32, AB 31, AB 100, A-B 100, AB 170, A-B 170, A-BG 1701

General

InstrumentSaphyRAD C1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Bertin TechnologiesProduct page Product page; Product page – Characteristics of the probes Checked 2026-10-16
SaphyRAD C
Bertin

SaphyRAD C

Contamination meter

Energy range
Alpha: 3–8 MeV; beta: 100 keV–2.2 MeV
IP rating
IP52, monitor and probes
Weight
650 g
12 referenced values
PA-100 Detector
Rotem

PA-100 Detector

Air proportional alpha detector with a 100 cm² sensitive area

Detector
Air proportional alpha detector
Weight
1 kg
9 referenced values
GM-10 Detector
Rotem

GM-10 Detector

Pancake GM probe for alpha, beta and gamma surface contamination

Detector
Pancake GM tube LND 73118 or equivalent; mica window 1.5–2.0 mg/cm² behind a fine stainless-steel wire mesh
Count-rate range
0–42,000 cps
Weight
370 g (0.8 lb)
8 referenced values
INNOPROBE
ORTEC

INNOPROBE

Alpha/beta probe for the RADEAGLET-R

Detector type
Alpha/beta-sensitive scintillator with photomultiplier (ZnS:Ag)
Count-rate range
Up to 25 kcps alpha and 20 kcps beta
Weight
300 g (0.66 lb)
15 referenced values