LUNG COUNTER

Lung counter for measuring radioactivity in the lungs

Counting system for fast and reliable radiometric checks of human lungs. Two NaI(Tl) detectors on a height-adjustable table are aimed at the lungs while the person sits in a chair, and the software converts count rates into activity in the lungs and committed effective dose using response curves from Monte Carlo simulations.

Detector type
Two cylindrical 5 × 4 in NaI(Tl) crystals with PMT1
Energy range
30 keV–3 MeV1
Spectrum channels
2,0481
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Detectors move independently left and right
  • Customisable limits, isotope library and reports
  • Mechanics and measuring equipment can be customised

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeTwo cylindrical 5 × 4 in NaI(Tl) crystals with PMT1

Performance

Energy resolution at 662 keV<7% (¹³⁷Cs)1

Measuring range

Energy range30 keV–3 MeV1

Electronics & signal

Spectrum channels2,0481

Software & data

SoftwareEfficiency curves from Monte Carlo calculations; activity (Bq) homogeneously dispersed in the lungs following the IDEAS guidelines’ models; customisable activity limits, isotope library and reports; good-functioning check1

Power & battery

Power supply230 V AC, 50 Hz1

Mechanical

DimensionsTable plane 700 × 1200 mm; table height 1060–1510 mm1
WeightApprox. 110 kg including all components1

General

Lead shieldingLow-background lead, 50 mm rings with 1 mm Cu inserts1
ConstructionTable with up/down movement to align the detectors; detectors move independently left/right on a rail; chair with armrests and footrest; laptop with software2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ELSE NUCLEARDatasheet p. 2, Technical Specifications; p. 2, Management software Checked 2026-10-16
  2. 2
    Publisher: ELSE NUCLEARProduct page Product page Checked 2026-10-16
VEBOS helkroppsräknare
ELSE NUCLEAR

VEBOS helkroppsräknare

In-vivo counting system

Detector options
HPGe or NaI(Tl), according to selected configuration
Total weight
Approximately 1000 kg
16 referenced values
FREE-AND 16
ELSE NUCLEAR

FREE-AND 16

Spectrometric station with 16 NaI(Tl) for waste characterisation

Detector type
16 NaI(Tl) 3 × 3 in crystals with PMT and MCA, eight on each side in two arrays
9 referenced values
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ARCHIMEDES III
ELSE NUCLEAR

ARCHIMEDES III

Portal monitor for excavation materials in boxes and containers

Detector type
Four plastic scintillators 100 × 50 × 5 cm
Active area
5000 cm² per detector; two pairs mounted on the sides of the portal
Energy range
35 keV–2 MeV
8 referenced values