SpectroTRACER

Spectrometric environmental probe

A system for continuous nuclide-specific detection of gamma activity in air, soil or water.

Detector options
LaBr₃: 1.5″×1.5″ or 1″×1″; NaI(Tl): 3″×3″ or 2″×2″; CeBr₃: 1.5″×1.5″1
Energy range
30 keV–2 MeV or 30 keV–3 MeV, configurable1
Spectrum channels
8,1921

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Versions for air/soil and water.
  • For low levels of gamma contamination.
  • Continuous spectrometric measurement.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Measuring range

Energy range30 keV–2 MeV or 30 keV–3 MeV, configurable1
Spectroscopic dose-rate range1 nSv/h–3 mSv/h, crystal dependent1

Electronics & signal

Spectrum channels8,1921

Connectivity & interface

Data storage2 GB1
CommunicationCellular, ShortLINK, satellite, Wi-Fi, Ethernet/DSL; ANSI N42.421

Environment & ratings

Operating temperature−20 to +50 °C; optional −30 to +60 °C1
IP ratingProbe: IP68; battery backup enclosure: IP651

Ordering & accessories

Detector optionsLaBr₃: 1.5″×1.5″ or 1″×1″; NaI(Tl): 3″×3″ or 2″×2″; CeBr₃: 1.5″×1.5″1
Optional GM dose-rate rangeUp to 1 Sv/h; extended to 10 Sv/h1

General

Measurement mediumAir/Soil: air/soil; Aqua: water1
Measurement functionsNuclide-specific gamma spectrometry and H*(10) dose rate1
Measurement cycle2 min–24 h; 2 configurable cycles1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Bertin TechnologiesProduct page product page; product page – technical specifications Checked 2026-10-16
AlphaE
Bertin

AlphaE

Ultra-small radon meter for concentration, personal exposure and dose

Detector type
Diffusion chamber with silicon diode
Measurement range
20 Bq/m³–10 MBq/m³
Weight
165 g
16 referenced values
Alpha S
Bertin

Alpha S

Portable radon monitor for air, soil and water

Detector type
Pulse ionisation chamber, 0.2 L
Measurement range
Up to 200,000 Bq/m³ (5.4 nCi/L)
Weight
<5.7 kg
12 referenced values
RCP
Bertin

RCP

Radiation portal monitor for pedestrian access control

Detector type
PVT plastic scintillator with large-diameter, low-noise PMT
Energy range
30 keV–5 MeV
10 referenced values
RCCL
Bertin

RCCL

Radiation portal monitor for small containers, luggage and parcels

Detector type
PVT plastic scintillator with large-diameter, low-noise PMT
Energy range
30 keV–5 MeV
8 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.