RDS Beta Photon Probe

Beta/photon probe with two GM tubes

Probe for the RDS Base Unit that measures beta and photon (gamma and X-ray) radiation with one GM tube for low and one for high dose. The end cap comes off for beta radiation and low-energy X-rays, and the probe fits the Telescoping Probe Handle for reaching further.

Detector type
Low-dose and high-dose Geiger-Mueller tubes1
Energy range
Photons 60 keV – 3 MeV; beta 200 keV – 3 MeV1
Count-rate range
0–1.5 Mcpm1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-11-16

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • Two GM tubes, low and high dose
  • Removable end cap for beta
  • Fits the Telescoping Probe Handle

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeLow-dose and high-dose Geiger-Mueller tubes1
Window1.7 ± 0.3 mg/cm² mica, protected by a stainless steel screen (79% open)1

Performance

Dead time50 µs1
Background rateTypically 60 cpm (in a 10 µR/h field)1
Detection efficiency4π: Pu-239 15%, Tc-99 19%, Sr-90/Y-90 22%, C-14 5%, P-32 32%1

Measuring range

Dose-rate range0.1 µGy/h – 100 Gy/h (gamma/X-ray)1
Energy rangePhotons 60 keV – 3 MeV; beta 200 keV – 3 MeV1
Count-rate range0–1.5 Mcpm1

Power & battery

Power supplySupplied by the RDS Base Unit1

Mechanical

Dimensions24 × 3 × 4 cm (9.26 × 1.2 × 1.6 in)1
Weight0.35 kg1
Housing materialAnodised aluminium1

Environment & ratings

Operating temperature−30 to 50 °C1
Storage temperature−50 to 60 °C1
Humidity3–100% relative humidity1
IP ratingIP671

Ordering & accessories

Part numberV0382761

General

Standards metANSI N42.17 and N42.34; MIL-STD 461F, 1686C and 810G1
NATO Stock Number (NSN)6665-01-671-43521

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Ludlum MeasurementsDatasheet p. 2, Radiological; p. 2, Radiological – Detection; p. 2, Radiological – Beta Window; p. 2, Radiological – Efficiency (4π) … Checked 2026-11-16
RDS Base Unit
Ludlum

RDS Base Unit

Survey meter and common base unit for the RDS probes

Detector type
Low-dose and high-dose Geiger-Mueller tubes
Energy range
Photons 60 keV – 3 MeV; beta 200 keV – 3 MeV
IP rating
IP67
16 referenced values
RDS FIDLER Probe
Ludlum

RDS FIDLER Probe

FIDLER probe for low-energy X-ray and gamma radiation

Detector type
NaI(Tl) scintillator, 127 mm diameter × 1.66 mm
Count-rate range
0–1.5 Mcpm
Weight
3.60 kg
14 referenced values
RDS Neutron Probe
Ludlum

RDS Neutron Probe

Solid-state neutron probe, helium-3-free

Detector type
Advanced solid-state neutron detector, helium-3-free
Weight
5.33 kg
IP rating
IP67
17 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.